IM301CNT – Iris IM301CNT, 2 digital counters

Block SymbolLicensing group: UNIPI
Qt SVG Document Exported by REXYGEN Studio HLD R1 R2 VALID err_id y1 y2 IM301CNT

Function Description
The IM301CNT block enables the use of digital inputs as counters on the Unipi Iris module. For more details, visit the manufacturer’s website [1].

This block does not propagate the signal quality. More information can be found in the 1.4 section.

Input

HLD

Hold

Bool

R1

Reset counter

Bool

R2

Reset counter

Bool

Parameter

slot

Slot

Long (I32)

0 ....

Not used

12 ...

Slot#12

22 ...

Slot#22

32 ...

Slot#32

42 ...

Slot#42

52 ...

Slot#52

11 ...

Slot#11

21 ...

Slot#21

debounce1

Debounce time in 100 μs   0  65535 1

Long (I32)

debounce2

Debounce time in 100 μs   0  65535 1

Long (I32)

reset_value1

Counter reset value   4294967295

Word (U16)

reset_value2

Counter reset value   4294967295

Word (U16)

Output

VALID

Data validity indicator

Bool

err_id

Error ID

Long (I32)

y1

Counter value   4294967295

Word (U16)

y2

Counter value   4294967295

Word (U16)

2024 © REX Controls s.r.o., www.rexygen.com