VTOR – Vector demultiplexer
Block SymbolLicensing group: STANDARD
Function Description
The VTOR block splits the input vector signal into individual signals. The user defines the
starting item and the number of items to feed to the output signals using the offset and n
parameter respectively. The etype parameter can be used to define the type of the output
values. If the vector connected to the input uVec has a different type, it will be
converted.
This block propagates the signal quality. More information can be found in the 1.4 section.
Input
uVec | Vector signal | Reference |
Parameter
n | Number of valid outputs 0 8 8 | Long (I32) |
offset | Index of the first output 0 | Long (I32) |
etype | Type of elements 8 | Long (I32) |
|
|
|
Output
y1..y8 | Analog output of the block | Double (F64) |
[Previous] [Back to top] [Up]