SGEN – Synchronous generator model
Block SymbolLicensing group: MODEL
Function Description
The function block description is not yet available. Below you can find partial description of
the inputs, outputs and parameters of the block. Complete documentation will be available in
future revisions.
This block does not propagate the signal quality. More information can be found in the 1.4 section.
Input
uf | Feed voltage [V] | Double (F64) |
rpm | Rotation per minute | Double (F64) |
pload | Load active power [W] | Double (F64) |
qload | Load reactive power [VAr] | Double (F64) |
MODE | 1=grid operation, 0=island operation | Bool |
R1 | Model state reset | Bool |
Parameter
pn | Nominal power [VA] 1.0 | Double (F64) |
un | Nominal RMS voltage [V] 1.0 | Double (F64) |
fn | Nominal frequency [Hz] 1.0 | Double (F64) |
ifn | Nominal feed current [A] | Double (F64) |
pp | Number of polpairs 1 10000 2 | Long (I32) |
ZM | on=constant impedance mode, off=constant power mode | Bool |
ra | Stator winding resistance [p.u.] 0.011 | Double (F64) |
rf | Feed winding resistance [p.u.] 0.0006 | Double (F64) |
r1d | D-axis damping winding resistance [p.u.] 0.0354 | Double (F64) |
r1q | Q-axis damping winding resistance [p.u.] 0.0428 | Double (F64) |
ld | D-axis stator winding self inductance [p.u.] 1.05 | Double (F64) |
lq | Q-axis stator winding self inductance [p.u.] 0.7 | Double (F64) |
lad | D-axis damping winding self inductance [p.u.] 0.9 | Double (F64) |
laq | Q-axis damping winding self inductance [p.u.] 0.55 | Double (F64) |
lff | Feed winding self inductance [p.u.] 1.571 | Double (F64) |
lf1d | Feed damping winding mutual inductance [p.u.] 0.9 | Double (F64) |
l11d | D-axis stator and damping winding mutual inductance [p.u.] 1.1 | Double (F64) |
l11q | Q-axis stator and damping winding mutual inductance [p.u.] 0.8067 | Double (F64) |
Output
if | Feed current [A] | Double (F64) |
u1 | 1st phase actual voltage [V] | Double (F64) |
u | RMS (phase) voltage [V] | Double (F64) |
i | RMS (phase) current [A] | Double (F64) |
p | Active power [W] | Double (F64) |
q | Reactive power [VA] | Double (F64) |
freq | Frequency [Hz] | Double (F64) |
phir | Rotor actual angle [rad] | Double (F64) |
phiu | Load/torque angle[rad] | Double (F64) |
phim | Mains-genertor phase difference [rad] | Double (F64) |
mload | Shaft torque [Nm] | Double (F64) |
E | Error indicator | Bool |