VOUT – Validation of the output signal
Block SymbolLicensing group: STANDARD
Function Description
It is possible to use the VOUT block to force arbitrary quality flags for a given
signal. The desired quality flags are given by the input signal iqf. Further details about
quality flags can be found in chapter 1.4 of this manual.
This block does not propagate the signal quality. More information can be found in the 1.4 section.
Input
u | Input signal requiring quality flags modification | Any |
iqf | Desired quality flags | Long (I32) |
Output
yq | Resulting composed signal | Any |