INCONN – Block for remote value acquirement

Block SymbolLicensing group: STANDARD
Qt SVG Document Exported by REXYGEN Studio

Function Description
The INCONN block allows for remote reading of parameter values (as well as inputs and outputs) of other blocks, similar to GETPR, GETPS, GETPA, and others. Its use is particularly suitable in situations requiring a quick response, such as in time-critical tasks.

The sc parameter, which specifies the path to the target parameter, must be given as either a relative path or a relative to task path (see the documentation for the GETPR block). This means the INCONN block must be placed within the same task as the target parameter, regardless of their hierarchical levels. Unlike the GETP blocks, the sc parameter cannot be modified during runtime.

The data type of the val output is determined by the type of the read value. Unlike the GETP blocks, the INCONN block does not allow for a one-time read setting. The value is refreshed in every execution period.

This block does not propagate the signal quality. More information can be found in the 1.4 section.

Parameter

sc

String connection to the parameter

String

Output

val

Parameter value

Any

2024 © REX Controls s.r.o., www.rexygen.com